We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Portable Anesthesia Vaporizer Machine Veterinary Pet Anesthesia Machine

Item No.: OLV-V1
Compact light-weight and portable, could be transported by pull-rod case, put on table and assembly on the trolley.
Description
Description
OLIVE delivery high precision veterinary anaesthesia equipment  with ventilation manage system . It is suitable for animal hospital, pet clinic and animal laboratory. This technical index of animal anaesthesia machine can meet the needs of general anesthesia and medical research on mice, dogs, cats, rabbits, monkeys, pigs, sheep and other animals in animal laboratory.
Technical Specification
Application 0.5-100kg animal
Ventilation mode Closed,half-closed,half-open
Tidal volume 10-2000ml
Oxygen source pressure 0.25~0.65Mpa
Airway pressure scope 030~60CMH2O
Flow Control 0-4L/min
Oxygen Flush 35L/min~75L/min
Pop adjust scope Directs the waste anesthetic gas from the machine to a scavenging system.
In the completely open position, the pop-off valve will release pressure at 2 cm H2O,
while maintain a constant passive volume in the breathing bags. 
Inspiration impedance ≦0.6Kpa
Expiration impedance ≦0.6Kpa
Absorption tank capacity 700ml
Monitoring Airway pressure,Gas source pressure monitoring
I:E As doctor need
BPM As doctor need
Configuration list
Main unit 1 Include the flowmeter,CO2 absorber,selectatec bar,chassis,oxygen flush
Anesthesia Vaporizer 1 Isoflurane,Halothane,Sevoflurane, Enflurane
With temperature, flow and pressure compensation
Breathing circuit 1  
Gas airbag0.5L,1L,3L 3  
Reusable Silicon pipeline 1 Ф22×1000
Oxygen hose 1  
Y-connector 1 With pressure differential sampling connector
Trolley 1  
Regulator Optional  
Anesthesia ventilator Optional Model:OLV-80V or OLV-60V
Anesthesia monitor Optional Anesthesia monitor
Non-Breathing circuit Optional  
Veterinary Mask Optional OLV-M80
Laryngoscope Optional  
Endotracheal intubation Optional  
Exhaust gas recovery tank Optional OLV-DE0602

******Suitable for small animals, Non-breathing circuit(Jackson or Bains Absorber) is available
******Selectatec-bar and quick change vaporizer mounting device
******Professional airtight breathing circuit design, provide the stable gas anesthesia, save anesthesia gas consumption, to ensure a clean operating room and laboratory environment.
******External and reusable soda lime canister, easily watch and replace soda lime.
******With Oxygen flush function to ensure that clinical anesthesia demand and oxygen supply demand
******Anaesthesia CO2 absorber assembly has no dead angle design, fast anesthesia, short recovery and high precision. The CO2 absorber supports both open loop and closed loop anaesthesia design and provides independent access .
******Provide a special Pop-Off  valve,Occlusion design, it can  connected to the exhaust gas recovery system and provide a continuous 2 cmH2O negative pressure for the reaspirato airbag ,reducing valve to prevent pressure to hurt the animal, ensure the animal safety .  
******Provides an accurate oxygen flow meter with a display range of 0 to 4LPM
******Vaporizer: the output concentration is not affected by the change of flow, pressure and temperature, accurate and reliable, equipped with safety locking device to prevent anesthetic leakage. Isoflurane,sevoflurane and halothane vaporizer are optional.
******The hard aluminum solid shell is used, and the surface sanding treatment is adopted, so that the cleaning and disinfection are more convenient.
******Visible inspiration and expiration valve
******Specifically designed to accomodate low flow anesthesia

Send your message to us