OLIVE delivers high-precision veterinary anesthesia equipment with a ventilation management system. It is suitable for an animal hospital, pet clinic and animal laboratory. This technical index of animal anesthesia machines can meet the needs of general anesthesia and medical research on mice, dogs, cats, rabbits, monkeys, pigs, sheep, and other animals in animal laboratories.
Technical Specification
Application
0.5-100kg animal
Ventilation mode
Closed,half-closed, half-open
Tidal volume
10-2000ml
Oxygen source pressure
0.25~0.65Mpa
Airway pressure scope
030~60CMH2O
Flow Control
0-4L/min
Oxygen Flush
35L/min~75L/min
Pop adjust scope
Directs the waste anesthetic gas from the machine to a scavenging system. In the completely open position, the pop-off valve will release pressure at 2 cm H2O, while maintaining a constant passive volume in the breathing bags.
Inspiration impedance
≦0.6Kpa
Expiration impedance
≦0.6Kpa
Absorption tank capacity
700ml
Monitoring
Airway pressure, Gas source pressure monitoring
I: E
As doctor need
BPM
As doctor need
Configuration List
Main unit
1
Include the flowmeter, CO2 absorber, selected bar, chassis, oxygen flush
Anesthesia Vaporizer
1
Isoflurane,Halothane,Sevoflurane, Enflurane With temperature, flow, and pressure compensation
Breathing circuit
1
Gas airbag0.5L,1L,3L
3
Reusable Silicon pipeline
1
Ф22×1000
Oxygen hose
1
Y-connector
1
With pressure differential sampling connector
Trolley
1
Regulator
Optional
Anesthesia ventilator
Optional
Model:OLV-80V or OLV-60V
Anesthesia monitor
Optional
Anesthesia monitor
Non-Breathing circuit
Optional
Veterinary Mask
Optional
OLV-M80
Laryngoscope
Optional
Endotracheal intubation
Optional
Exhaust gas recovery tank
Optional
OLV-DE0602
Suitable for small animals, a Non-breathing circuit(Jackson or Bains Absorber) is available
Selected-bar and quick change vaporizer mounting device
Professional airtight breathing circuit design, provides stable gas anesthesia and saves anesthesia gas consumption, to ensure a clean operating room and laboratory environment.
External and reusable soda lime canister, easily watch and replace soda lime.
With Oxygen flush function to ensure that clinical anesthesia demand and oxygen supply demand
Anesthesia CO2 absorber assembly has no dead angle design, fast anesthesia, short recovery and high precision. The CO2 absorber supports both open-loop and closed loop anaesthesia design and provides independent access .
Provide a special Pop-Off valve, Occlusion design, that can connected to the exhaust gas recovery system and provide a continuous 2 cmH2O negative pressure for the reaspirato airbag, reducing valve to prevent pressure from hurting the animal, ensuring the animal safety.
Provides an accurate oxygen flow meter with a display range of 0 to 4LPM
Vaporizer: the output concentration is not affected by the change of flow, pressure and temperature, accurate and reliable, and is equipped with a safety locking device to prevent anesthetic leakage. Isoflurane,sevoflurane and halothane vaporizer are optional.
The hard aluminum solid shell is used, and the surface sanding treatment is adopted, so that the cleaning and disinfection are more convenient.
Visible inspiration and expiration valve
Specifically designed to accommodate low-flow anesthesia
As a company with 15+ years of experience, we have the appropriate expertiseQ and technical facilities to provide our customers with high quality products.